BIDFINDER

Sources Sought · DKGV-1137999

Repair Naval Reserve Training Facility B3370

Department of the Air Force · Charleston AFB, SC

This is a notice (Sources Sought), not a request for offers.

Agency
Department of the Air Force FederalFA4418 628 Cons PK
Place
Charleston AFB, SC
Offers due
April 1, 2029, 12:00 PM (ET) closes in 874 days
Estimated value
not stated
Notice type
Sources Sought
Category
Maintenance and repair
NAICS code
236220 Commercial and Institutional Building Construction
Product service code (PSC)
Z2AA
Set-aside
Small Business Set Aside - Total
Posted
March 18, 2026
Solicitation number
DKGV-1137999
Open the official notice

Opens the notice on SAM.gov, with its attachments and how to respond.

New bids by email: Maintenance and repair in South Carolina

At most one email a day, only when there are new bids. You confirm by email and can unsubscribe in one click. Privacy

Source: SAM.gov Contract Opportunities, the U.S. government's official list of federal contract opportunities.

Description

The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Naval Reserve Training Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 - Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00

Browse more bids

More open bids from this agency

Similar open bids